R&D & Testing
The bending test of the stiles is the one buyers ask for first — it proves the rail carries a person at mid-span. Here is the bench, the standard clauses, and the deflection figures recorded per ladder family.
Engineering that answers to a number
Our engineers set the stile profile, rung pitch and locking mechanism, then prove them on our own bench before anything is sent for a type test.
Two ladders that pass a GS test on the same clause can still differ by ten millimetres of deflection — and that difference is what separates a quiet product from a warranty claim. So every model carries its own record: standard set applied, clause number, support span, and the deflection actually measured against the allowance.


Bench records, in full
Same test, two ladder types. The load is identical; what changes is how many times the ladder has to be tested and how much deflection the span allows.
Extension ladder — bending test of the stiles
GS tested · TÜV SÜD · clause 4.11


Multi-function ladder — bending test of the stiles
GS tested · TÜV Rheinland · clause 9.8


Note: these two records reproduce published third-party bench reports used as the format reference for this page — clause numbers, certificate numbers, spans and measured deflections are theirs, not Alico's own bench sheets. Alico's type-test file for a specific SKU is released with the quotation.
How the test is run
Four moves, every time — so a result from 2016 can be read against one taken this morning.
Where the allowance comes from
Three span bands, one formula each: the permissible bending deflection grows with span but penalises long ladders, so a 6 m ladder is allowed far less relative travel than a 3 m one.
Set the supports
Ladder horizontal, supports 200 mm from each end; one roller free to turn so the ladder is not clamped in place.
Pre-load 100 N for 1 min
Take the slack out of the assembly, release, and set that position as the origin for the measurement.
Apply 750 N for 1 min
Load spread over 100 mm at mid-span, split equally between both stiles, applied without jerks.
Read against f max
Deflection is measured after the pre-load is removed; the ladder passes when Δf stays inside the allowance for its span.
New product introduction
From your drawing to a loaded container — a new SKU walks through five gates, each with an owner and a document that leaves the building with it.
Specification
Target market, standard class, load rating and packaging brief agreed in writing.
Design & tooling
Profile drawings, mould and fixture design, material grades fixed.
Prototype
First-off samples built on the real line, benched and re-cut before tooling sign-off.
Type test
Witnessed testing to EN 131 for the CE / GS file; internal report signed by QC.
Pilot & release
Pilot batch, carton drop test, then volume production and shipping samples.
Want the test file for a specific ladder?
Tell us the SKU or the market you are buying for. We send back the standard class, the bench sheet and the packaging drawing with the quotation.