Manufacturing since 1999ISO 9001 · CE / GS tested+86-22-24457169sales@alico-ind.com
R&D & TestingProduct CatalogGet a Quote

R&D & Testing

The bending test of the stiles is the one buyers ask for first — it proves the rail carries a person at mid-span. Here is the bench, the standard clauses, and the deflection figures recorded per ladder family.

750 NTest load F at centre
100 N · 60 sPre-load before origin
Z1A 081955 0010Extension ladder certificate
S 50477832 0003Multi-function certificate

Engineering that answers to a number

Our engineers set the stile profile, rung pitch and locking mechanism, then prove them on our own bench before anything is sent for a type test.

Two ladders that pass a GS test on the same clause can still differ by ten millimetres of deflection — and that difference is what separates a quiet product from a warranty claim. So every model carries its own record: standard set applied, clause number, support span, and the deflection actually measured against the allowance.

Aluminium multi-function ladder on the bending bench Fibreglass dual function ladder prepared for testing

Bench records, in full

Same test, two ladder types. The load is identical; what changes is how many times the ladder has to be tested and how much deflection the span allows.

Extension ladder — bending test of the stiles

GS tested · TÜV SÜD · clause 4.11

Certificate No.Z1A 081955 0010
EN 131-1:2015+A1:2019EN 131-2:2010+A2:2017EN 131-3:2018

Method — carried out on the complete ladder, fully extended. Supports 200 mm in from each end, cylindrical Ø 25–100 mm, one free to rotate and one fixed. Load applied slowly at mid-span over 100 mm, shared equally by both stiles.

Pre-load100 N · 1 min · origin taken after release
Test load F750 N · 1 min · applied vertically at centre
Support span l3 000 mm · 200 mm from each end
Permissible f max45.0 mm · 5 l² · 10⁻⁶
Measured Δf26.93 mm · below the allowance
Deflection vs. permissible59.8 %
Pass18.1 mm of allowance unused at a 3 m span.
Extension ladder model covered by the bench recordExtension ladder · model in file
Step ladder model covered by the bench recordStep ladder · model in file

Multi-function ladder — bending test of the stiles

GS tested · TÜV Rheinland · clause 9.8

Certificate No.S 50477832 0003
EN 131-1:2019EN 131-2:2010+A2:2017EN 131-3:2018EN 131-4:2020

Method — same set-up and same load, but a combination ladder is tested twice: once with the middle hinge up, then rotated 180° about its longitudinal axis with the hinge down, because the climbable side is not fixed by construction.

Test load F750 N · 1 min · after a 100 N pre-load
Support span l2 990 mm · 200 mm from each end
Permissible f max44.70 mm · 5 l² · 10⁻⁶
Δf · hinge up42.35 mm · pass
Δf · hinge down36.55 mm · rotated 180°
Hinge up vs. permissible94.7 %
Hinge down vs. permissible81.8 %
PassTightest case: 2.35 mm left at the hinge-up position.
Multi-function ladder loaded at mid-spanMulti-function ladder · model in file
Deflection reading during the testSteel step ladder · model in file

Note: these two records reproduce published third-party bench reports used as the format reference for this page — clause numbers, certificate numbers, spans and measured deflections are theirs, not Alico's own bench sheets. Alico's type-test file for a specific SKU is released with the quotation.

How the test is run

Four moves, every time — so a result from 2016 can be read against one taken this morning.

f max = 5 l² · 10⁻⁶ mmladders ≤ 5 m span f max = 0.043 l − 90 mm5 m < l ≤ 12 m f max = 0.06 l − 294 mml > 12 m
i

Where the allowance comes from

Three span bands, one formula each: the permissible bending deflection grows with span but penalises long ladders, so a 6 m ladder is allowed far less relative travel than a 3 m one.

01

Set the supports

Ladder horizontal, supports 200 mm from each end; one roller free to turn so the ladder is not clamped in place.

02

Pre-load 100 N for 1 min

Take the slack out of the assembly, release, and set that position as the origin for the measurement.

03

Apply 750 N for 1 min

Load spread over 100 mm at mid-span, split equally between both stiles, applied without jerks.

04

Read against f max

Deflection is measured after the pre-load is removed; the ladder passes when Δf stays inside the allowance for its span.

New product introduction

From your drawing to a loaded container — a new SKU walks through five gates, each with an owner and a document that leaves the building with it.

Gate 01

Specification

Target market, standard class, load rating and packaging brief agreed in writing.

Gate 02

Design & tooling

Profile drawings, mould and fixture design, material grades fixed.

Gate 03

Prototype

First-off samples built on the real line, benched and re-cut before tooling sign-off.

Gate 04

Type test

Witnessed testing to EN 131 for the CE / GS file; internal report signed by QC.

Gate 05

Pilot & release

Pilot batch, carton drop test, then volume production and shipping samples.

23QC inspectors
5NPI gates per SKU
EN 131Bending bench procedure
CE·GSType-test documentation

Want the test file for a specific ladder?

Tell us the SKU or the market you are buying for. We send back the standard class, the bench sheet and the packaging drawing with the quotation.